There are three classes of intensifiers.
Air over oil intensifier circuit.
The optional stainless steel output cylinder can handle a wide range of liquids.
The pump s usual discharge pressure is of the order of 16000 psi.
Contact bimba for seal compatibility.
As a result the output.
The air pump draws the hydraulic oil from the reservoir and pumps it to the intensifier circuit which has manual valves and pressure gauges.
The cylinder strokes are made to order and dictate output volume.
Air input to the intensifier s spring return retracts the piston drawing in hydraulic oil from a reservoir and pumps it to the intensifier circuit at a pre defined output hydraulic to input air pressure ratio.
The simple design offers a quick response and trouble free operation.
More cost efficient alternative to full hydraulic cylinder.
A vented spring chamber eliminates back pressure.
Air input to the intensifier s spring return retracts the piston drawing in hydraulic oil from a reservoir and pumps it to the intensifier circuit at a pre defined output hydraulic to input air pressure ratio.
The air operated pump delivers oil on to the top piston of the intensifier with the valves a and b shut.
Its operation is quite simple.
Riveting crimping punching swaging trimming marking or character stamping assembly notching joining forming and fastening models.
Intensifiers also known as boosters use a large quantity of low pressure fluid to produce a smaller quantity of higher pressure fluid.
Too much back pressure in the exhaust line may cause some intensifiers to stall.
This in turn drives a smaller diameter ram or piston to deliver a given volume of fluid.
Pressurized fluid either air or oil enters the intensifier and acts on a confined piston.
Intensifier is filling with oil.
Ah series hi lo air over oil cylinder.
This type of circuit requires very good cylinder seals to prevent air or oil transfer.
Click here to view sample circuit drawing.
Intensified oil circuit all components in the high pressure hydraulic or air circuit should have a safety factor of at least 6 1.
Typical air oil tank arrangement.
Air oil intensifier circuit with purchased reciprocating intensifier.
A vented spring chamber eliminates back pressure.
When control is only necessary in one direction the tank on the uncontrolled side can be omitted.
4 tons 8 tons 10 tons 15 tons 20 tons 30 tons 50 tons 4 tons to 50 tons of hydraulic force.
When a machine needs a low to medium volume of high pressure oil and has long holding times use a reciprocating intensifier.
Single shot design incorporates various ratios between the air piston supply and intensified air or oil output.
Air over oil tanks do not intensify the oil pressure regardless of the tank s diameter or length.
If necessary to run a long exhaust line make it about two pipe sizes larger than the feed line.